Products |
| Cardio-Vascular Group >
Critical Care > Trauma Catheter Products |
Trauma
Catheter Products
Double Lumen High Flow Catheters
|
 |
|
|
 |
High Flow Standard
Catheter Sets |
| |
|
| |
|
| |
VARR
CS12802 |
Two-Lumen Central Venous Catheterization
Set with Blue FlexTip® Catheter |
5/case |
| One: |
Two-Lumen Indwelling
Catheter: 8 Fr. x 6-1/4" (16 cm) Radiopaque Polyurethane
with Blue FlexTip®, Extension Line Clamps, Injection Site
Caps |
| One: |
Spring-Wire Guide,
Marked: .032" (.81 mm) dia. x 17-13/16" (45 cm) (Straight
Soft Tip on One End - "J" Tip on Other) with Arrow
Advancer™* |
| One: |
Catheter: 18 Ga.
x 2-1/2" (6.35 cm) Radiopaque over 20 Ga. RW Introducer
Needle |
| One: |
Fastener: Catheter
Clamp |
| One: |
Introducer Needle:
18 Ga. x 2-1/2" (6.35 cm) XTW |
| One: |
Syringe: 5 cc Luer-Slip |
| One: |
Tissue Dilator |
| One: |
Clamp: Catheter |
| * US Patent
No. 5,484,419. |
|
| |
Top |
| |
VARR
CS15802 |
Two-Lumen Central Venous Catheterization
Set with Blue FlexTip Catheter |
5/case |
| One: |
Two-Lumen Indwelling
Catheter: 8 Fr. x 8" (20 cm) Radiopaque Polyurethane with
Blue FlexTip®, Extension Line Clamps, Injection Site Caps |
| One: |
Spring-Wire Guide,
Marked: .032" (.81 mm) dia. x 23-5/8" (60 cm) (Straight
Soft Tip on One End – “J” Tip on Other) with
Arrow Advancer™* |
| One: |
Fastener: Catheter
Clamp |
| One: |
Introducer Needle:
18 Ga. x 2-1/2" (6.35 cm) XTW |
| One: |
Catheter: 18 Ga. x
2-1/2" (6.35 cm) Radiopaque over 20 Ga. RW Introducer Needle
with 5 cc Luer-Slip Syringe |
| One: |
Clamp: Catheter |
| One: |
Tissue Dilator |
| *US Patent No. 5,484,419. |
|
| |
Top |
| |
VARR
SI11142 |
MAC™ Two-Lumen Central Venous
Access Set With Integral Hemostasis Valve/Side Port for use
with 7 - 8 Fr. Catheters |
5/case |
| One: |
Sheath: 9 Fr. x 4"
(10cm) Radiopaque Polyurethane |
| One: |
Spring-Wire Guide,
Marked: .035" (.89 mm) dia. x 17-13/16" (45 cm) (Straight
Soft Tip on One End - "J" Tip on Other) with Arrow
Advancer™* |
| One: |
Introducer Needle:
18 Ga. x 2-1/2" (6.35 cm) XTW |
| One: |
Pressure Transduction
Probe |
| One: |
Arrow® Raulerson
Spring-Wire Introduction Syringe*: 5 cc |
| One: |
Dust Cap: Vented |
| One: |
Dust Cap: Non-Vented |
| One: |
Cath-Gard® Catheter
Contamination Shield: 80 cm with Tuohy-Borst Adapter, Sterile
Tape |
| One: |
Tissue Dilator |
| Three: |
Gauze Pad(s): 4"
x 4" |
| One: |
Obturator: 8 Fr. |
| One: |
Stopcock: 4-way High-Flow |
| One: |
Injection Site Cap |
* Licensed under US Patent
Nos. 4,813,938 and 5,045,065.
* US Patent
No. 5,484,419. |
|
| |