mayohealthcare logo  
 
Custom Search
       
 

Products

Respiratory Group > Anaesthesia Breathing Circuits

Anaesthesia Breathing Circuits
Disposable Anaesthetic Breathing Systems

  1. Adult Basic Anaesthetic Breathing Systems
  2. Entonox (N2O & O2) Delivery Systems
  3. UniFlow Universal Coaxial Breathing Systems for Low Flow Anaesthesia
  4. Clear-Flo Circle Systems with Spherasorb Soda Lime  
  5. Open Anaesthetic Breathing Systems - Mapleson Classification
  6. Paediatric Anaesthetic Breathing Systems
  7. MRI Circuits

      Paediatric Anaesthetic Breathing Systems
   
    Circle breathing systems 15mm - Intersurgical (ISG)
   
Product Code Description Length Luer Elbow Water Trap Unit
/Case
2142 ISG - 15mm breathing system 1.6 m   10
2143 ISG - 15mm breathing system 1.6 m 10


    Mapleson F Breathing System Classifications - Intersurgical (ISG)
   
Product Code Description Length Open tail bag Unit
/Case
2120 ISG - Infant T-piece system 1.8 m   10
2143 ISG - Jackson Rees modification with detachable elbow 1.8 m 0.5 Litre 15


    Top
    Paediatric Anaesthetic Breathing Systems with APL Valve - Intersurgical (ISG)
   
In order to allow for effective scavenging from paediatric anaesthetic breathing systems Intersurgical has developed the paediatric APL valve. The most important consideration in the development of the valve was safety. The majority of hospitals can deliver a maximum of 15L/min from their oxygen flow meters and therefore this was taken as the basis to limit the amount of pressure generated.

The maximum pressure the paediatric APL valve can generate in the closed position at 15L/min is 35cm H2O. The paediatric APL valve used in the following breathing systems can provide safer and effective scavenging.


    Bagging Systems
The paediatric bagging system incorporates a CO2 monitoring elbow at the patient end for direct sampling. This system can be utilised in a wide range of clinical applications including physiotherapy, patent transfer, and resuscitation and may be used for both spontaneously breathing and hand ventilated patiens in operating departments.


Product Code Description Length Reservoir Bag Unit
/Case
2124INT ISG - Paediatric bagging system 1.8 m 0.5 Litre 15
2126INT ISG - Paediatric bagging system 1.8 m 1 Litre 10


    Direct Gas Delivery System
A direct gas delivery system which minimises the deadspace at the patient connection and reduces rebreathing to a minimum. The system is compact and convenient and has a 1 litre reservoir bag.


Product Code Description Length Reservoir Bag Unit
/Case
2123INT ISG - Paediatric direct gas delivery system 1.8 m 1 Litre 15


    Infant T-Piece System
An infant T-piece system with the paediatric APL valve positioned away from the patient allowing spontaneous and hand ventilation whilst preserving the clinical field around the patient. It is based on the Jackson Rees modification with a closed tail bag.


Product Code Description Length Reservoir Bag Unit
/Case
2122 ISG - Mapleson F - T-piece with paediatric APL valve 1.8 m 0.5 Litre 15


    Top
    Anaesthesia Circuits - Mayo Healthcare Range (MHC)
   
Features and Benefits
  • Multiple versions
  • Custom design upon request
  • All required parts glued

   
Product Code Size Wye Tubing
ID (mm)
Tubing
Length
Bag
(Litre)
99119 Paediatric Fixed 15 1.5m (60”) 0.5
99105 Paediatric Fixed 15 3m (120”) 0.1





    Top
    T Circuits - Mayo Healthcare Range (MHC)
   
Features and Benefits
  • Paediatric
  • Custom design upon request
  • Elbow

   
Product Code Tubing
ID (mm)
Tubing
Length
Bag
(Litre)
Oxygen Tubing Washington
99240 22mm 46cm (18”) 1  
99241 15mm 50cm (20”) 0.5  
99262 15cm 60cm (24”) 0.5  
99322     0.5
99323     0.1





    Top
    Resuscitation Circuits - Mayo Healthcare Range (MHC)
   
Features and Benefits
  • Multiple versions
  • Custom design upon request
  • Specifc for the ICU environment

   
Product Code Size Elbow Tubing
ID (mm)
Tubing
Length
Bag
(Litre)
Oxygen Tubing
99066A Paediatric   22 46 cm 0.5
99067A Paediatric 22 15 cm 2





     
    For more information please contact us on 1300 360 226
or email to
Mayo Healthcare Customer Service





    Top
 
» Disposable Anaesthetic Breathing Systems
» Disposable Anaesthetic Accessories
» Emergency Care
» Alterna Reusable Breathing Systems and Accessories
 
Absorbants
Adaptors
Aerosol Therapy
Airway Management
Anaesthesia Breathing Circuits
Critical Care Breathing Circuits
Filters
Hospital Labeling Systems
Humidification
Incentive Spirometers
Interventional Hygiene
Laryngeal Masks
Oxygen Therapy
Suction Equipment
 
Download Acrobat Reader
Click here to download Acrobat Reader
 
 

       
      Last modified: January 21, 2008
Copyright© 2003 - 2009 Mayo Healthcare Pty Ltd
Mayo Healthcare Pty Ltd & Mayo Hardware Pty Ltd are subsideries of Mayo Group Int. Pty Ltd

  Customer Service: 1300 360 226
Email: surgcserv@mayohealthcare.com.au